LEVEL INSTRUMENT
 
MODULEVEL
ECLIPSE

KOTRON 804

 

 

ECHOTEL 344
Technology
  
Buoyancy& Range Spring
(Displacement Type)
Guided Wave Radar
  
RF Capacitance
  
Ultrasonic Non Contact
  
Application
  
  
  
  
Feedwater heater,
Scrubbers, Boilers,
Receivers,Separators
and Condensate drip pots
  
Chemical Storage or
process tanks, sumps,
pits or open channel,
High Temperature and
High Pressure Fluids
Clean or dirty liquids,
Viscous Slurries,
High - Temperature and
High - Pressure Fluids
  
Sump & wastewater,
Slurries, Viscous Fluids,
Pulp and Paper,
Power, Petrochemicals
  
Application
sensitivies
Variable SG
  
Bridging
  
Variable Dielectric,
Conductive Coating
Foam, Vapors, Severe
Turbulance
Mounting
Arrangement
Top, Cage
(Side/side or Side/Bottom)
Top, Cage
(Side/side or Side/Bottom)
Top
  
Top
  
  
Connection
Size
 
 
  
Top (3",4",6" Flange)
Cage (1 1/2",2" in NPT,
SW, Flanged)
  
Top (3/4" NPT, 2" NPT,
2",3",4",5" in Flanged)
Cage (1 1/2",2" in NPT,
SW, Flanged)
Sanitary Flange
  
3/4" NPT,
Option : Flanged
Sanitary Flange
  
2" NPT,
Option : Flanged
  
  
  
Material
  
CS or 316 SS Body
316 SS Displacer
316 SS or hastelloy
or monel probe
316 SS or TFE
Insulated Probe
Kynar Transducer
  
Spon/Level
Range
  
14", 32", 48", 60"
72",84",96",108",120"
  
24" to 240" W/Rigid -
Probe, 1m to 15m w/
Flexible Probe
6" to 234" W/Rigid -
Probe, 3m to 45m w/
Flexible Probe
  
10 Meter
  
 
 
Function
 
 
Electrical : Transmitter
Pneumatic : Transmitter
Proportional (or w/reset),
Differential Gap
  
  
  
Transmitter
  
  
  
  
Transmitter or/and Switch
  
  
  
  
Transmitter or/and Switch
  
  
Power
Supply
24 VDC Loop Power,
120 VAC, 240 VAC
24 VDC Loop Power
  
24 VDC,
120 VAC, 240 VAC
24 VDC,
120 VAC, 240 VAC
  
Output
  
4-20 mA, HART,
or Pneumatic
(3-15 PSI / 6-30 PSI)
 
4-20 mA, HART
 
 
4-20 mA, RS485, HART
 
 
4-20 mA, RS232
 
Press Max
5000 PSIG
5000 PSIG
5000 PSIG
50 PSIG
Temp Max
700° F
750° F
1000° F
163° F
Accuracy
+/- 1%
+/- 0.1%
+/- 1%
+/- 0.25%
Required
Additional
Information
  
SG
  
  
Dielectric, Viscocity
  
  
Dielectric
  
  
Structures within the vessel
  
 
<< Back